Type
Filter
B56: Ball valve, metal, electrically operated, one-piece body, compact flange, low-maintenance spindle seal and blow-out-proof shaft, with anti-static unit
DN
Filter
15: DN 15
20: DN 20
25: DN 25
32: DN 32
40: DN 40
50: DN 50
65: DN 65
80: DN 80
100: DN 100
Body configuration
Filter
D: 2/2-way body
U: 2/2-way straight through body, V-ball 30° (KV value see data sheet)
W: 2/2-way straight through body, V-ball 90° (KV value see data sheet)
Y: 2/2-way straight through body, V-ball 60° (KV value see data sheet)
Connection type
Filter
39: Flange ANSI Class 125/150 RF, face-to-face dimension FTF EN 558 series 1, ISO 5752, basic series 1, length only for body configuration D
68: Flange EN 1092, PN 16 / PN40, form B DN 15 to DN 50, flange EN 1092, PN 16, form B DN65 to DN 100
Ball valve material
Filter
37: 1.4408 / CF8M (body, connection), 1.4401 / SS316 (ball, shaft)
Liner material
Filter
5: PTFE
Voltage/Frequency
Filter
C1: 24VDC
L2: 230V 50Hz
L3: 230V 60Hz
N2: 400V 50Hz
N4: 400V 50/60Hz
R5: 15-30V 50/60Hz 12-48VDC
T5: 100-240VAC 50/60Hz 100-350VDC
U5: 24V-240V AC / DC for model 20, 35, 55, 85, 140, 300
Y5: 24VDC 85-260VAC
Control module
Filter
00: OPEN/CLOSE control, relay not reversible
0E: OPEN/CLOSE control, 2 additional potential-free limit switches, relay not reversible
A0: OPEN/CLOSE control
A31: ON/OFF actuator, 3-position actuator, additional potential-free limit switches, Failsafe battery pack (NC), preferred direction adjustable
A3: ON/OFF actuator, 3-position actuator, additional potential-free limit switches
AB1: OPEN/CLOSE control, 2 additional potential-free limit switches, additionally a potential-free error output for current limitation (max. torque exceeded), thermal limitation and program error, failsafe battery pack (NC), preferred direction adjustable
AB2: OPEN/CLOSE control, 2 additional potential-free limit switches, additionally a potential-free error output for current limitation (max. torque exceeded), thermal limitation and program error, failsafe battery pack (NO), preferred direction adjustable
AB: OPEN/CLOSE control, 2 additional potential-free limit switches, 2 additional potential-free torque switches, class A (EN15714-2)
AE1: OPEN/CLOSE control, 2 additional potential-free limit switches, BSR battery pack (NC)
AE2: OPEN/CLOSE control, 2 additional potential-free limit switches, BSR battery pack (NO)
AE: OPEN/CLOSE control, 2 additional potential-free limit switches, Class A (EN15714-2)
ALS: OPEN/CLOSE actuator, 2 additional potential-free limit switches, on-site control, basic (Logic ON/OFF), (S4 30% duty, 120 starts/hour, actuator class A/B)
AP: OPEN/CLOSE control, potentiometer output, class A (EN15714-2)
AT: OPEN/CLOSE actuator, analog position feedback, external set value 0/4-20mA, 2 additional potential-free limit switches
E11: Positioner DPS, external set value 0-10V, BSR battery pack (NC)
E1: Control module, external set value 0-10 VDC
E21: Positioner DPS, external set value 4-20mA, BSR battery pack (NC)
E2: Control module, external set value 0/4-20mA
EB1: POSI positioner, 2 additional potential-free limit switches, control and feedback signal, adjustable to 0-20mA/4-20mA/0-10V, failsafe battery pack (NC), preferred direction adjustable
EB2: POSI positioner, 2 additional potential-free limit switches, control and feedback signal, adjustable to 0-20mA/4-20mA/0-10V, failsafe battery pack (NO), preferred direction adjustable
EB: Control module without control, external wiring necessary, 2 additional potential-free limit switches, additional potential-free torque switches
ELM: Position control, 2 additional potential-free limit switches, MODBUS RTU, local control, basis (Logic Positioner), (S4 50% ED, 360 starts / hour, actuator class C)
ELP: Position control, 4-20mA input and output, on-site control, 2 additional potential-free limit switches, PROFIBUS DPV1, on-site control, basic (Logic Positioner), (S4 50% duty, 360 starts/hour, actuator class C)
ELS: Position control, external set value 4-20mA, input and output, 2 additional potential-free limit switches, basic (Logic positioner) (S4 50% duty, 360 starts/hour, actuator class C)
EMR: MODBUS RTU
Actuator version
Filter
2070: Actuator, motorized, operating time 15s, torque 70Nm, GEMUE, size 2 supply voltage C1
3015: Actuator, motorized, operating time 11s, torque 15Nm, GEMUE, size 3 supply voltage B1, C1
4100: Actuator, motorized, operating time 20s, torque 100Nm, GEMUE, size 4 supply voltage C1
4200: Actuator, motorized, operating time 16s, torque 200Nm, GEMUE, size 4 supply voltage C1
J4C14: Actuator, motorized, operating time 34 s, torque 140 Nm, J+J, type J4, heating, IP67
J4C20: Actuator, motorized, operating time 9s, torque 20Nm, J+J, type J4 heating, IP67
J4C30: Actuator, motorized, operating time 58 s, torque 300 Nm, J+J, type J4, heating, IP67
J4C35: Actuator, motorized, operating time 9s, torque 35Nm, J+J, type J4 heating, IP67
J4C85: Actuator, motorized, operating time 29 s, torque 85 Nm, J+J, type J4, heating, IP67
VR25: Actuator, motorized, operating time 7s, torque 25Nm, BAR/VALPES, V series
VR45: Actuator, motorized, operating time 15s, torque 45Nm, BAR/VALPES, V-series
VR75: Actuator, motorized, operating time 20s, torque 75Nm, BAR/VALPES, V-series
VS150: Actuator, motorized, operating time 30s, torque 150Nm, BAR/VALPES, V-series OPEN/CLOSE control, STV-VSA150-90A-H00
VS300: Actuator, motorized, operating time 60s, torque 300Nm, BAR/VALPES, V-series
Execution type
Filter
OHNE
5227: Thermal break between actuator and valve body by mounting bridge, mounting bridge and mounting parts in stainless steel
Special version
Filter
OHNE
X: ATEX certification
CONEXO
Filter
OHNE
C: Integrated RFID chip for electronic identification and traceability