Glossaire GEMÜ pour vannes et

composants d'automatisation

Glossaire GEMÜ pour vannes et

L1 – L4 Plus
​Abbreviation for laboratory safety measures The necessary measures for ensuring safety in biotechnological laboratories are listed in the publication "Safe Biotechnology", Part 2 (Leaflet M 056) of the Trade Co-operative Association of the Chemical Industry.
Moins
LAL Plus
​​Limulus-Amöbozyten-Lysat See also Limulus Test
Moins
Laminar flow Plus
​A laminar flow is a flow of gases and liquids around obstructions, which does not result in any flow turbulence. This means that the medium flows past the obstruction closely without becoming mixed up.
Moins
Leaching effect Plus
​Through certain media, low-molecular organic compounds are released from parts of a material. As a result, organic compounds from the piping system enter into the medium.
Moins
Lethality factor (L) Plus
​Effectiveness of a sterilisation processGermocidal effect at a certain temperature in relation to the germicidal effect of the reference temperature.
Moins
Level Plus
​The level is the degree of the filling of a container. The level can usually be measured by the height of the medium in the container.
Moins
Limit value Plus
​Permissible value which, according to laws, regulations, etc. must not be exceeded. According to the TVO, the limit value for the colony count in drinking water is: 100 germs/1 ml; for Escherichia coli (E. coli) in drinking water = 0 germs/100 ml, see also TVO Moins
Limulus test Plus
​Method for proving endotoxins by yellowing See also Pyrogenic
Moins
Log reduction Plus
​Alternative form of the D-value For example reduction by three powers of 10 (10 –3) = log3 or 3D-reduction.
Moins
Long-stroke Plus
​Term used in linear operating valves, cylinders and combustion engines The opening stroke/piston stroke is longer than the nominal diameter of the valve seat/piston.
Moins
Long-term pasteurisation Plus
​See also pasteurising
Moins
Low germ Plus
​Low colony number (germ number). In relation to a product low germ means that the biological stability is statistically guaranteed
Moins
Low pasteurising Plus
​​See pasteurising
 
Moins
Low pasteurising Plus
See Pasteurising
Moins
Machine Plus
​A machine is a connected network of parts of which at least one part is freely maovable. A machine is used to perform technical processing stages and to optimize these in terms of force, time and accuracy.
Moins
Machine Plus
​A machine is a connected network of parts, of which at least one part is freely movable. A machine is used to perform technical processing stages and to optimize these in terms of force, time and accuracy.
Moins
Machinery Directive Plus
​This directive regulates the framework conditions for occupational health and safety in connection with machines. It lays down requirements with regard to conformity assessment procedures for persons responsible for machines.
Moins
Manipulated variable "y" Plus
​Is the value by which the valve is actuated to achieve matching set and actual values.
The manipulated variable can be implemented electrically, hydraulically or pneumatically (depending on the implemented system technology).
Moins
Maximum permissible operating pressure Plus
​Is the maximum permissible pressure of the working medium defined by the manufacturer for which a component or device is designed and at which the function and operational reliability are still guaranteed.
The maximum permissible operating pressure is always dependent/interactive with the maximum permissible operating temperature and ambient temperature. The interactions in plastic pressurised components are so strong that they must be taken into account and might mean that they cannot be used. In other cases the interactions must at least be checked. A reference temperature for the working medium and the environment of 20 °C usually serves to determine the maximum permissible operating pressure defined by the manufacturer. If the actual temperature of the working medium or the environment deviates from the manufacturer reference, the user must limit the maximum operating pressure accordingly or use more stable components. If the maximum operating pressure is permissible at simultaneously high temperatures, the manufacturer will define this accordingly in the documentation.
Moins
Maximum permissible operating temperature Plus
​Is the maximum permissible temperature of the working medium defined by the manufacturer for which a component or device is designed and at which the function and operational reliability are still guaranteed.
The maximum permissible operating temperature is always dependent/interactive with the maximum permissible operating pressure and prevailing ambient temperature. The interactions in plastic pressurised components are so strong that they must be taken into account and might mean that they cannot be used. In other cases the interactions must at least be checked. A reference pressure for the working medium and an ambient temperature of 20 °C usually serves to determine the maximum permissible operating temperature defined by the manufacturer. If the actual pressure of the working medium or the ambient temperature deviates from the manufacturer reference, the user must limit the maximum operating temperature accordingly or use more stable components. If the maximum operating temperature is permissible at simultaneously high operating pressure and/or increased ambient temperature, the manufacturer will define this accordingly in the documentation.
Moins
Mean roughness value Plus
​See Roughness parameters
Moins
Measurement Plus
Is the comparison of an unknown variable with a similar scaled known variable.
Moins
Measurement device Plus
​Is a device which continuously measures a mathematical, geometrical, chemical, physical or time variable directly (e.g. thermometer) or indirectly (e.g. turbine flow transmitter), processes it internally in a suitable form if necessary and shows it in a display.
Short definition: measurement is sensing and if necessary processing and displaying.
Moins
Measuring transducer Plus
​Is a device which continuously measures an electrical variable on the input side, converts it internally and provides it on the output side in another electrical variable as a signal for further processing (e.g. 2-wire measuring transducers which pick up a physical variable on the input side by a potentiometric sensor and provide it as a current signal for further processing on the output side).
Moins
Micro filtration Plus
Micro filtration is a membrane filtration process which works with pressure. The pore size is > 0,1 µm.
Moins
Micro-organisms Plus
​Bacteria, yeasts, mould fungi, algae; possibly viruses and bacteriophages.
Examples of dimensions:
Viruses = 17 - 300 µm,
bacteria = 0,2 - 3 µm,
yeasts = 2 - 8 µm.
Moins
Microbiocide Plus
​Germocidal
Microbiocidic materials have an exterminating effect on micro-organisms.
Moins
MIF Plus
​Magnetically inductive flowmeter. Through the application of a magnetic field and the voltage occurring as a result of the deflection of the load carrier, which is generated by the flowing medium in a pipe, the flow velocity can be calculated based on its proportionaliy to the voltage.
Moins
MIF Plus
​​Milk Industry Foundation
Moins